T568a vs T568b, Which to Use

T568a vs T568b: Which To Use

Written by Don Schultz, trueCABLE Senior Technical Advisor, Fluke Networks Copper/Fiber CCTT, BICSI INST1, INSTC, INSTF Certified


Sometimes choosing between two technically different options, especially if you are a novice, is a tough decision. Which way do you go, and how do you find out? Well, you came to the right blog and video! When terminating the end(s) of Ethernet cable, you have to follow a certain color code scheme, T568A or T568B. This scheme is designed to help the installer get the conductor wires into the right order so that your cable will work properly. Get this part wrong, and you may end up with a non-working cable run. Whether it be an 8P8C RJ45 plug, keystone jack, or patch panel this holds true regardless of what kind of termination you are performing.  And it does not matter if it is Cat5e, Cat6, Cat6A, or Cat8.

Confusion and Controversy

There are two schemes: T568A and T568B. From a practical standpoint, they perform and function identically in a modern data network. Just be sure you are using the same color scheme at both ends of your cable and you will stay out of trouble. I happen to prefer “B”. Why? I got lazy and did not want to memorize “A”. Fifteen years ago I might have given you a different answer, but things change.

T568A and T568B are the termination standards used by Internet backbone infrastructure, Internet providers and all the way down to homeowners or businesses. The only real difference between these two pin-to-pair assignments are the green and orange pairs. These two sets are swapped in the cable. Even though these are switched, they are still both effectively direct or “straight through” connections.

t568a and t568b pinouts

 

There is misinformation out there on this topic, fortunately most of it benign. This misinformation is not malicious, but sometimes people get used to doing something a certain way and then it becomes “gospel”. The culprit is often out of date information.

There are rare instances (like US government contractual requirements) when T568A may be specifically called out for use. Unless you have a customer dictating which one to use, then T568A versus T568B comes down to personal preference. If you don’t have any specific requirements to use one over the other, then simply pick one and stick with it. You don’t need to research any further.

 

 

The color code schemes are defined by the ANSI Accredited Telecommunications Industry Association (ANSI/TIA). In the absence of a stated customer requirement, the 2018 dated ANSI/TIA 568.2-D revision sets the commercial building standard for how to match twisted pair wires to a plug or socket. ANSI/TIA 570-D sets the residential standard. However, the standards have changed over time and this takes some by surprise, leading to confusion and misinformation. It also leads to lively debates!

As of 2018, ANSI/TIA still recommends T568A for residential installations for plug-in backward compatibility with old technology like fax machines or a plug-in base station for wireless phone handsets. If you are not using any such devices, or have no intention of plugging ancient RJ11 plugs into RJ45 wall jacks like you would a “phone jack”, then it comes back to personal preference again. In reality, just how many people are using this old equipment any longer? I personally switched over to cell phones in 2006 and have not looked back.  

In the past, specifically with the old TIA/EIA 568-B-2 revision written and ratified around 2001, this recommendation was different for commercial and US government spaces. TIA recommended T568A at that time and further notated US government contracts require T568A. This was to maintain backward compatibility with older equipment like in the residential space (fax machines, etc.) As of the “D” revision, this is no longer the case and that recommendation and notation have been removed. The ANSI/TIA 568.2-D commercial standard is now mute on the subject unless you have a contractual or technical reason to go with one or the other. There is a warning in the commercial standard about making certain that both ends of the cable are terminated to the same scheme. In other words, pick one and stick with it.

So now that we have sorted out what the actual recommendations are, another common misconception is that one wiring scheme will perform better than the other. Let me put this to bed immediately: they are identical in regards to performance. I decided to conduct a test to prove this out.

Test conditions, components, and setup:

  • 292 feet of trueCABLE Cat6A Riser U/UTP Ethernet cable
  • Two trueCABLE Cat6 unshielded tool-less keystone jacks (these are component rated and impedance matching grade keystones)
  • Fluke DSX-8000, in calibration, 6.5 B5 firmware, using the permanent link adapters
  • A reference was set after a 10-minute warm-up of the Fluke DSX-8000
  • The first test conducted was with the keystone jacks terminated to the T568B pattern
  • The second test conducted was with the keystone jacks terminated to the T568A pattern
  • The same ends of the cable were used at the remote and main units for both tests
  • The same keystones used at the remote and main units were used on the same ends as well
  • The ambient temperature was 71 degrees Fahrenheit
  • The Cat6A cable was loosely coiled in three-foot coils, not actually installed

The results of the tests speak for themselves. It is a wash on performance.

t568a test results

T568A test

 

T568B test

T568B test

 

t568b test results

Summarized results

Crossover Cable

So, if there is a “straight through” kind of cable run there must be a “not” straight through type (logically speaking), correct? Well, indeed there is. It is called a “cross over” cable where one end is terminated to T568A and the other is terminated to T568B.  Where would one use that kind of thing?

TIA 568A TIA 568B and Cross-over cable diagram

 Images credit: Industrial Ethernet Book

 

In most network applications, the standard straight through cabling method is required. For example, a computer plugged into a wall panel uses the standard cable configured with either T568A or T568B termination. This allows the computer to communicate with other devices on the local area network. Whether talking to a network printer or mail server, the data traverses the network because all the cabling has been put together using one of the above termination standards. The same is true for the cabling in the wall and the patch panel where they all terminate.

Now for other applications, we may need to connect a computer directly to another computer or a host-to-host connection. As an example, we need to copy data from one computer to another, but the two computers don’t have access to a switch for help with this process. These two computers need to use a crossover cable.

Please note that the use of cross-over cables is very rare in the modern age. There are some specialized applications for them, but you will likely never see it in the wild.

Summing this up, the whole T568A vs T568B thing has been a needless source of confusion and controversy for over two decades. Understanding how the standards evolved and your chances of encountering a situation where you will be forced into using one scheme or the other is not likely to happen in this day and age. Just pick one and go. With that, I say…

 

HAPPY NETWORKING!

 

trueCABLE presents the information on our website, including the “Cable Academy” blog and live chat support, as a service to our customers and other visitors to our website subject to our website terms and conditions. While the information on this website is about data networking and electrical issues, it is not professional advice and any reliance on such material is at your own risk.

 

John March 21, 2023

I agree that there is no technical advantage of 568A over 568B, and no real difference when doing a cable run with a punch down product on either end. For me, the benefit of 568B is when having to make custom patch cables with RJ45 connectors on either end. All the CAT cable spools I have (and have ever come across) have orange diagonally across brown, and green diagonally across blue. Having orange and brown as the outer cable strands creates a more natural gap between them and makes it easier to spread the white-green and green strands apart to put the blue strands in between them. It can be done in the 568A configuration, but its more challenging to push the green strands and brown strands apart (since they are side by side) , put the blue strands between the white-orange and orange strands (again, side by side) and then squeeze them between the green and brown all the while trying to keep them flat and in line so they can be inserted into the RJ45 connector to be crimped. Use a CAT cable product that adds a spline to reduce crosstalk by separating the strands and 568B is the better option for making patch cords.

trueCABLE March 22, 2023

Hello John! I had not really thought of it from that perspective. Thanks for sharing your insight and experience.

Anthony April 20, 2023

I read through the info on the page here and I feel like I'm missing something. I am still new when it comes to dealing with networks outside of my personal use so I have not had a need to make cables. I have, however, done a good deal of electrical wiring. Functionally speaking, the color of the wires are meaningless. They are only colored to give us humans a reference point. The hot lead doesn't care if it's red or black as long as it is connected correctly. Is it not the same with this?

The devices you are connecting don't care that pin 3 is white/green instead of white orange as long as it is the same on both ends. From what I can tell, as long as you did it exactly the same on both ends, you could put the colors wherever you want and everything would function the same.

Not suggesting anyone do that! It's always best to follow industry standards!! Fastest way to make the next tech hate your guts is to do something completely random that only you understand. Doesn't matter if it works. I'm just exploring the question.

trueCABLE April 20, 2023

Hello, Anthony! Great question. You are correct in that electrons do not care about color. The color code is a human reference point. That said, it is NOT correct that you can simply match the colors at both ends and wire the way you want. The reason is that Ethernet has TWISTED pairs, and each pair is in electromagnetic balance. That is why there is a human reference point. If you were to match the colors at both ends and ignore the color code, you would likely have a out of balance cable and it would not work well or at all. We hope this helps!

    1 out of ...